Products 

 

 

 

 

 

 

 

 

 

 

 

   

Copyright © 2007

 

2000 Series Page Controls
 

V-2006AHF

6 Zone
Enhanced, Talkback
Power Built-In!

Valcom Power Units 
 

  

PDF Downloads

Marketing Sheet
Technical Specification

Installation Manual

International Version
Installation Manual

2000 Series Page Controls
  
GENERAL INFORMATION

  • Provides Tandem All Call

  • Background Music Input,
    Automatically Mutes In Zone
    Being Paged

  • Page Override For Special Or
    Priority Announcements

  • Features Are  Programmable Per Zone

  • Built-In Tone Generator For Night Ringing, Time Clock Tone, Door Bell

  • Accepts Pulse Dial And Tone Dial

  • Supports Up To 2 Talkback Speakers And 40 One-Way Speakers Per Zone

  • Battery Back-Up Input (VPB-260)

  • UL Listed/CE

ACCESS: Page Port on Selected Telephone Systems, PBX Loop Start or Ground-Start Trunk Port, Electronic or 1A2 Line Key (line card required), or Dedicated Single Line Phone Set.
Specifications:

Input Impedance
: 600 ohm
Music Source Impedance: 4 to 600 ohm
Music Input Level: -10 dBm nominal
DC Output: -24 Vdc @ 500 mA
Power
Requirements: 230 Vac/.5A or 120 Vac/1A

Weight: Weight:10.0 lbs (4.54 kg)
Dimensions: 10.25" H x 13.0" W x 2.63" D (26.0 cm x 33.02 cm x 6.68 cm)

International Version
6 Zone Enhanced
V-2006AHF-E
Power Requirements: 230 Vac/.5A