V-VCU
Clock Controller Package


- Provides power and data for Valcom 2-Wire Clock connection over a single par of wires
- User selectable correction intervals
- Data error LED indicators
- Power/data output LED indicators
Overview
The Valcom V-VCU 2-wire clock driver corrects Valcom analog and digital display clocks over a single pair of UTP cable. Time may be adjusted to update from once every second to once an hour.
Specifications
INPUT
RJ116 Pin connection to the V-DCPI Digital Clock Protocol Interface, V-GPS GPS Master Clock or V-WMC Wireless Master Clock Transceiver.
Voltage/Frequency: 120 Vac, 47-63 Hz
Power: 165 Watts
BTU/HR: 565
Protection: 4A/120Vac Line fuse
Connection: IEC 320 Input + AC cord
OUTPUTS
Voltage: 24Vdc Valcom 2-Wire Digital - regulated + 2% filtered, floating 10mV Ripple Maximum
Current: 6 Amps, Three (3) 2A clock outputs
Protection: Three 2 An auto-reset poly switches
ENVIRONMENT
Temperature: 32 to 104°F (0 to 40°C)
Humidity: 10-90% Non-condensing
MOUNTING
Wall or shelf mount
DIMENSIONS & WEIGHT
Dimensions: 2.0in H x 7.0in W x 5.75in D
5.08cm x 17.78cm x 14.61cm
Weight: 11.6lbs (5.26kg)
APPROVALS
UL, cUL Listed
Class 2 Power Supply
FCC Class B
ACCESSORIES
VP-6124-UPS Charging unit
VBB-1424 Battery Box/Batteries
Resources
Drawings
valcom-wired-head-end-gps-master-clock-correction-scenario-2-wire-digital-multiple-vccu042.dwg
Downloadalcom-wired-head-end-gps-master-clock-correction-scenario-2-wire-digital-multiple-vccu042.pdf
Downloadvalcom-connections-for-2-wire-digital-clock-correction-when-for-application-server-and-ve8048023.pdf
Downloadvalcom-connections-for-2-wire-digital-clock-correction-when-for-application-server-and-ve8048023.dwg
DownloadInstallation Manuals
Marketing Sheet
Technical Specifications
How To Buy
US Distributors

Target

TeleDynamics

Communications Supply Corporation (CSC)

Jenne