Valcom Clocks Wire Gauge Guide
Using 24 AWG UTP for 24V Clocks | |||||
Clock Display | 1 Clock Per Wire Run | 5 Clocks Per Wire Run | 10 Clocks Per Wire Run | 15 Clocks Per Wire Run | 20 Clocks Per Wire Run |
Analog | 3000ft 914 m | 1000ft 304 m | 600ft 183 m | 400ft 121 m | 300ft 91 m |
2.5" Digital | 1500ft 457 m | 500ft 152 m | 250ft 76 m | N/A | N/A |
4.0" Digital | 400ft 121 m | 100ft 30 m | N/A | N/A | N/A |
Using 20 AWG for 24V Clocks | |||||
Clock Display | 1 Clock Per Wire Run | 5 Clocks Per Wire Run | 10 Clocks Per Wire run | 15 Clocks Per Wire Run | 20 Clocks Per Wire Run |
Analog | 7000ft 2130 m | 2500ft 762 m | 1400ft 427 m | 1000ft 304 m | 750ft 229 m |
2.5" Digital | 3900ft 1189 m | 1300ft 396 m | 700ft 213 m | N/A | N/A |
4.0" Digital | 900ft 274 m | 300ft 91 m | N/A | N/A | N/A |